R&M MiniCore Singlemode 2-fiber G657.A2 R878983
- Brand: R&M
- Product Code: R878983
- Availability: In Stock
MiniCore cable, aerial-drop, universal-use, no armour, FRLSZH sheath - black, Fca, 02-fibers G657.A2
Environmental Characteristics
Temperature cycling | -10 °C +60 °C / +14 °F +140 °F |
Temperature cycling acceptance criteria | Δα ≤ 0,05 dB |
Temperature cycling test method | IEC 60794-1-22:F1 |
Operation temperature | -10 °C to +60 °C / +14 °F to +140 °F |
Storage / Transport temperature | -10 °C to +60 °C / +14 °F to +140 °F |
Thermal load | 0.11 MJ/m |
Flammability vertical single cable | Pass |
Flammability vertical single cable test method | IEC 60332-1-2 |
Smoke density | Pass |
Smoke density test method | IEC 61034-2 |
Halogen free, acid gases | Pass |
Halogen free, acid gases test method | IEC 60754-2 |
2015 / 863 / EU - RoHS 3 | conform |
Technical Data
Cable family code | IFAF |
Cable type | FiTH Cable |
Cable version | Gel-free installation cable |
Cable application | indoor use |
CPR classification | Dca-s1a,d0,a1 |
DoP number | D9087 |
Fiber type | G.657.A2 |
Fiber count | 2 |
Fiber color coding | 1.–4.: red, green, blue, yellow |
Loose tube count | 1 |
Loose tube diameter | 1,15 mm |
Outer sheath material | FRLSZH |
Outer sheath color | yellow |
Cable outer diameter | 2,3 mm |
Cable weight | 5.5 kg/km / 4 lbs/1000ft |
DIN / VDE 0888 code | J-B(ZN)H |
Warranty | R&Mfreenet |
Expected lifetime | min. 30 years |
CPR classification | Dca |
Mechanical Data
Installation tensile strength | 200 N (5 min) |
Installation tensile strength acceptance criteria | Δα ≤ 0,05 dB |
Installation tensile strength test method | IEC 60794-1-21:E1 |
Crush resistance long term | 400 N/100mm (15 min) |
Long-term crush resistance acceptance criteria | Δα ≤ 0,05 dB prior release, no damage |
Long-term crush resistance test method | IEC 60794-1-21:E3A |
Short-term crush resistance | 1000 N/100mm |
Short-term crush resistance acceptance criteria | Δα ≤ 0,05 dB after release, no damage |
Short-term crush resistance test method | IEC 60794-1-21:E3A |
Impact resistance | 3 Nm, 3 impacts, d=20 mm, R=12.5 mm |
Impact resistance acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Impact resistance test method | IEC 60794-1-21:E4 |
Kink | d=4 x cable diameter |
Kink acceptance criteria | no kink |
Kink test method | IEC 60794-1-21:E10 |
Repeated bending | R=20 x cable diameter, 25 cycles |
Repeated bending acceptance criteria | no damage |
Repeated bending test method | IEC 60794-1-21:E6 |
Cable bend | d=20 x cable diameter, 4 turns, 3 cycles |
Cable bend acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Cable bend test method | IEC 60794-1-21:E11A |
Minimum bend radius in service | 35 mm |
Minimum bend radius during installation | 45 mm |