R&M Fiber Optic Cable 24 core Single Mode, G657A1, green, Dca  R855651

R&M Fiber Optic Cable 24 core Single Mode, G657A1, green, Dca R855651

  • Brand: R&M
  • Product Code: R855651
  • Availability: In Stock


Central loose tube, single sheathed cable, iRP-increased rodent protected, universal-use, UV.FRLSZH sheath - green, Dca, 01 x 24 fibers OM4 G657A1

Technical Data

Cable family code UX1GF
Cable type Central loose tube cable
Cable version n.a.
Cable application universal use
CPR classification Dca-s2,d1,a1
DoP number D9031
Fiber type G.657.A1
Fiber color coding 1.-12.: red, green, blue, yellow, white, gray, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, gray, brown, violet, turquoise, natural, orange, pink(ring-marked)
Fiber count per tube 24
Loose tube count 1
Loose tube diameter 3 mm
Armor powerful rodent protected
Outer sheath thickness 1.2 mm
Outer sheath material UV stable FRLSZH
Outer sheath color green
Cable outer diameter 7.2 mm
Cable weight 58.0 kg/km / 39 lbs/1000ft
DIN / VDE 0888 code U-DQ(ZN)BH
CPR test method EN 50575, EN 13501-6
Standard put-up length on drum 2100 m ± 5%
CPR classification Dca

Mechanical Data

In-service tensile strength 800 N
In-service tensile strength acceptance criteria Δα ≤ 0,05 dB
In-service tensile strength test method IEC 60794-1-21:E1
Installation tensile strength 2000 N
Installation tensile strength acceptance criteria Δα ≤ 0,05 dB after test
Installation tensile strength test method IEC 60794-1-21:E1
Crush resistance long term 1000 N/100mm
Long-term crush resistance acceptance criteria Δα ≤ 0,05 dB prior release, no damage
Long-term crush resistance test method IEC 60794-1-21:E3A
Short-term crush resistance 2000 N/100mm
Short-term crush resistance acceptance criteria Δα ≤ 0,05 dB after release, no damage
Short-term crush resistance test method IEC 60794-1-21:E3A
Impact resistance 10 Nm, 3 impacts, d=20 mm, R=300 mm
Impact resistance acceptance criteria Δα ≤ 0,05 dB after test, no damage
Impact resistance test method IEC 60794-1-21:E4
Torsion L = 1 m, rotation angle ±180°, 10 cycles
Torsion acceptance criteria no damage
Torsion test method IEC 60794-1-21:E7
Repeated bending R=20 x cable diameter, 25 cycles
Repeated bending acceptance criteria no damage
Repeated bending test method IEC 60794-1-21:E6
Cable bend d=20 x cable diameter, 4 turns, 3 cycles
Cable bend acceptance criteria Δα ≤ 0,05 dB after test, no damage
Cable bend test method IEC 60794-1-21:E11A
Minimum bend radius in service 110 mm
Minimum bend radius during installation 150 mm

Environmental Characteristics

Temperature cycling -35 °C +70 °C / -31 °F +158 °F
Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible
Temperature cycling test method IEC 60794-1-22:F1
Reversible temperature cycling -30 °C +70 °C / -22 °F +158 °F
Reversible temperature cycling test method IEC 60794-1-22:F1
Operation temperature -30 °C to +70 °C / -22 °F to +158 °F
Thermal load 0.81 MJ/m
Flammability vertical single cable Pass
Flammability vertical single cable test method IEC 60332-1-2
Smoke density Pass
Smoke density test method EN 61034-1, EN 61034-2
Halogen free, acid gases Pass
Halogen free, acid gases test method EN 60754-2