R&M MiniCore Singlemode 2-fiber G657.A2 R878983

R&M MiniCore Singlemode 2-fiber G657.A2 R878983

  • Brand: R&M
  • Product Code: R878983
  • Availability: In Stock
  • 0.45€



MiniCore cable, aerial-drop, universal-use, no armour, FRLSZH sheath - black, Fca, 02-fibers G657.A2

Environmental Characteristics

Temperature cycling -10 °C +60 °C / +14 °F +140 °F
Temperature cycling acceptance criteria Δα ≤ 0,05 dB
Temperature cycling test method IEC 60794-1-22:F1
Operation temperature -10 °C to +60 °C / +14 °F to +140 °F
Storage / Transport temperature -10 °C to +60 °C / +14 °F to +140 °F
Thermal load 0.11 MJ/m
Flammability vertical single cable Pass
Flammability vertical single cable test method IEC 60332-1-2
Smoke density Pass
Smoke density test method IEC 61034-2
Halogen free, acid gases Pass
Halogen free, acid gases test method IEC 60754-2
2015 / 863 / EU - RoHS 3 conform

Technical Data

Cable family code IFAF
Cable type FiTH Cable
Cable version Gel-free installation cable
Cable application indoor use
CPR classification Dca-s1a,d0,a1
DoP number D9087
Fiber type G.657.A2
Fiber count 2
Fiber color coding 1.–4.: red, green, blue, yellow
Loose tube count 1
Loose tube diameter 1,15 mm
Outer sheath material FRLSZH
Outer sheath color yellow
Cable outer diameter 2,3 mm
Cable weight 5.5 kg/km / 4 lbs/1000ft
DIN / VDE 0888 code J-B(ZN)H
Warranty R&Mfreenet
Expected lifetime min. 30 years
CPR classification Dca

Mechanical Data

Installation tensile strength 200 N (5 min)
Installation tensile strength acceptance criteria Δα ≤ 0,05 dB
Installation tensile strength test method IEC 60794-1-21:E1
Crush resistance long term 400 N/100mm (15 min)
Long-term crush resistance acceptance criteria Δα ≤ 0,05 dB prior release, no damage
Long-term crush resistance test method IEC 60794-1-21:E3A
Short-term crush resistance 1000 N/100mm
Short-term crush resistance acceptance criteria Δα ≤ 0,05 dB after release, no damage
Short-term crush resistance test method IEC 60794-1-21:E3A
Impact resistance 3 Nm, 3 impacts, d=20 mm, R=12.5 mm
Impact resistance acceptance criteria Δα ≤ 0,05 dB after test, no damage
Impact resistance test method IEC 60794-1-21:E4
Kink d=4 x cable diameter
Kink acceptance criteria no kink
Kink test method IEC 60794-1-21:E10
Repeated bending R=20 x cable diameter, 25 cycles
Repeated bending acceptance criteria no damage
Repeated bending test method IEC 60794-1-21:E6
Cable bend d=20 x cable diameter, 4 turns, 3 cycles
Cable bend acceptance criteria Δα ≤ 0,05 dB after test, no damage
Cable bend test method IEC 60794-1-21:E11A
Minimum bend radius in service 35 mm
Minimum bend radius during installation 45 mm

Tags: MiniCore cable,