R&M Fiber Optic Cable 12 core OM3, green, Dca R853221
- Brand: R&M
- Product Code: R853221
- Availability: In Stock
Central loose tube, single sheathed cable, RP-rodent protected, universal-use, UV.FRLSZH sheath - green, Dca, 01 x 12 fibers OM3
Technical Data
Cable family code | UT1EF |
Cable type | Central loose tube cable |
Cable version | n.a. |
Cable application | universal use |
CPR classification | Dca-s2,d1,a1 |
DoP number | D9012 |
Fiber type | OM3 |
Fiber count | 12 |
Fiber color coding | 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink |
Fiber count per tube | 12 |
Loose tube count | 1 |
Loose tube diameter | 2,3 mm |
Armor | Rodent protection |
Outer sheath thickness | 1 mm |
Outer sheath material | UV stable FRLSZH |
Outer sheath color | green |
Sheath marking | Ink-Jet, black |
Cable outer diameter | 5,2 mm |
Cable weight | 33.0 kg/km / 22 lbs/1000ft |
DIN / VDE 0888 code | U-DQ(ZN)H wbg |
CPR classification | Dca |
Environmental Characteristics
Temperature cycling | -30 °C +70 °C / -22 °F +158 °F |
Temperature cycling acceptance criteria | Δα ≤ 0,05 dB |
Temperature cycling test method | IEC 60794-1-22:F1 |
Reversible temperature cycling | -35 °C +70 °C / -31 °F +158 °F |
Reversible temperature cycling acceptance criteria | Δα ≤ 0,15 dB, reversible |
Reversible temperature cycling test method | IEC 60794-1-22:F1 |
Operation temperature | -30 °C to +70 °C / -22 °F to +158 °F |
Storage / Transport temperature | -35 °C to +70 °C / -31 °F to +158 °F |
Thermal load | 0.48 MJ/m |
Flammability vertical single cable | Pass |
Flammability vertical single cable test method | IEC 61034-2 |
Flammability vertical cable bundle | Pass |
Flammability vertical cable bundle test method | IEC 60332-3-22 |
Smoke density | Pass |
Smoke density test method | IEC 61034-1, IEC 61034-2 |
Halogen free, acid gases | Pass |
Halogen free, acid gases test method | IEC 60754-2 |
2015 / 863 / EU - RoHS 3 | Pass |
Mechanical Data
In-service tensile strength | 300 N |
In-service tensile strength acceptance criteria | Δα ≤ 0,05 dB |
In-service tensile strength test method | IEC 60794-1-21:E1 |
Installation tensile strength | 1000 N |
Installation tensile strength acceptance criteria | Δα ≤ 0,05 dB after test |
Installation tensile strength test method | IEC 60794-1-21:E1 |
Crush resistance long term | 1000 N/100mm |
Long-term crush resistance acceptance criteria | Δα ≤ 0,05 dB prior release, no damage |
Long-term crush resistance test method | IEC 60794-1-21:E3A |
Short-term crush resistance | 2000 N/100mm |
Short-term crush resistance acceptance criteria | Δα ≤ 0,05 dB after release, no damage |
Short-term crush resistance test method | IEC 60794-1-21:E3A |
Impact resistance | 10 Nm, 3 impacts, d=20 mm, R=300 mm |
Impact resistance acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Impact resistance test method | IEC 60794-1-21:E4 |
Torsion | L = 1 m, rotation angle ±180°, 10 cycles |
Torsion acceptance criteria | no damage |
Torsion test method | IEC 60794-1-21:E7 |
Repeated bending | R=20 x cable diameter, 25 cycles |
Repeated bending acceptance criteria | no damage |
Repeated bending test method | IEC 60794-1-21:E6 |
Cable bend | R=20 x cable diameter, 4 turns, 3 cycles |
Cable bend acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Cable bend test method | IEC 60794-1-21:E11A |
Minimum bend radius in service | 80 mm |
Minimum bend radius during installation | 120 mm |